#RS922-7049 #Eaton xEffect FAZ MCB Mini Circuit Breaker 1P, 16 A, 10 kA, Curve D #FAZ-D16/1 #Eaton #누전차단기

#RS922-7049 

#Eaton xEffect FAZ MCB Mini Circuit Breaker 1P, 16 A, 10 kA, Curve D 

#FAZ-D16/1 

#Eaton 

#누전차단기

단가 : 28,000 원(VAT별도)


제품 세부 사항

Eaton FAZ Series MCBs

Eaton FAZ- miniature circuit breakers are Current limiting design provides fast short-circuit interruption that reduces the let-through energy that can damage the circuit, Trip-free design. Breaker cannot be defeated by holding the handle in the ON position

Features and Benefits

Thermal-magnetic overcurrent protection
Power to the circuit breakers can be fed from the line or load side
Clear indication of contact position via front switch toggle
Easy installation on DIN rail. Module width of only 17.5 mm (per pole)
Six levels of short-circuit protection, categorized by B, C, D, K, S and Z curves
Small modular width of the device and accessories saves space in the panel or equipment, which can lead to cost savings
Dual rated for IEC 60947-2 standard
Module widths: 1 Pole 17.5mm, 2 pole 35mm and 3 pole 52.5mm

Standards

IEC 60947-2 Relates to Low Voltage Circuit Breakers for use in industrial and similar
Installations. In the UK traditionally known as moulded case circuit breakers
(MCCB’s) and also air circuit breakers (ACB’s).
Q: What is the differences in the Tripping Curves B, C, D and S?

A: Curve B: Tripping: 3 to 5 times the rated current.
Applications: protection of generators, persons, very long cables
Curve C: Tripping: 5 to 10 times the rated current
Applications: protection of circuits and general applications
Curve D: Tripping: 10 to 14 times the rated current
Curve S Tripping 13 to 17 times the rated current
Suitable for applications where high levels of inrush current are expected. Instantaneous trip is 13–17X rating of device (In). The high magnetic trip point prevents nuisance tripping in high inductive applications such as motors, transformers and power supplies

Standards

IEC 898; BS/EN60-898; EN50 022/DIN46277-3 (BS5584).
FAZ-C*/* & FAZ-S*/* = IEC/EN60947-2
사양
속성
RangeXEffect
SeriesFAZ
Number of Poles1
Current Rating16 A
Tripping CharacteristicsType D
Rated AC Voltage240 V
Rated DC Voltage48V
Breaking Capacity10 kA
Length17.8mm
Width65.5mm
Depth80mm
Special FeaturesCurrent Limiting Design Provides Fast Short-Circuit Interruption, Designed for Highly Inductive Loads, Field-Installable Shunt Trip and Auxiliary Switch Subsequent Mounting, Possibility for Sealing the Toggle In ON or OFF Position, Suitable For Branch Circuit Device Protection, Thermal-Magnetic Overcurrent Protection
Break TimeInstantaneous
Terminal Contact TypeScrew
Tripping MechanismThermal-Magnetic
ApplicationAppliances, Business Equipment, Control Circuit, Lighting, Supplementary Protection
Reset Actuator TypeToggle Switch
Circuit Breaker TypeMCB

댓글

이 블로그의 인기 게시물

#RS533-279 #RS PRO Ratchet Crimping Tool for Terminal #압착기

#RS457-3710 RS PRO 3 wire PT100 Sensor, -50°C min +250°C max, 30mm Probe Length x 3mm Probe Diameter